Sold on its own
DNA and RNA extraction and quality control
Extraction is usually bought as the first step of a sequencing project. It can also be bought on its own, with its QC report, when you have material and want purified nucleic acid back.
Matrices
What we extract, and from what
DNA, RNA and protein, at high yield and purity, from the matrices we handle routinely:
- Blood, plasma and serum.
- Fresh and frozen tissue.
- Cells and cell pellets.
- FFPE blocks and sections.
- Saliva and buccal swabs.
- Stool and other microbiome matrices.
- Bacterial cultures.
Quantities to send are on the sample collection protocols page, matrix by matrix. If yours is not listed, describe it rather than assume it is impossible.
Deliverables
What you get back
Two things, and the second matters as much as the first:
- The purified material, in the buffer and format your downstream work needs.
- A documented QC report, delivered in your client portal: concentration by fluorometry, 260/280 and 260/230 purity ratios, and integrity scored by Bioanalyzer or TapeStation.
Every batch is tracked under chain of custody from reception to delivery, and the report is written to be audit-ready rather than merely informative.
How it is bought
On its own, or as a first step
Bought alone, the material is returned to you. Bought as the first step of a project, it goes straight to the next platform without a return shipment, which removes a transport leg and a freeze-thaw cycle. See the platforms it can feed.
Turnaround follows the usual rule: 3 business days for routine services (e.g. genotyping once the line is validated), and for a project 4–6 weeks as standard or 2–4 weeks as priority, in working days from GO, with a scoped date in your quote. See turnaround times.
Quality control
DNA and RNA quality control service
Concentration, purity and integrity, measured and documented. Available on material you extracted yourself, when you need a third measurement before committing a cohort to sequencing.
What we measure
Three quantities, each with the instrument that measures it properly:
- Concentration by fluorometry (Qubit), which reads only the nucleic acid you asked about.
- Purity, through the 260/280 ratio (about 1.8–2.0) and the 260/230 ratio (about 2.0–2.2), the usual targets on DNA.
- Integrity, by Bioanalyzer or TapeStation electrophoresis, scored as RIN for RNA and DIN for DNA.
Why it matters
Why a separate measurement is worth buying
A spectrophotometer reads everything that absorbs at 260 nm, including free nucleotides and residual contaminants. It therefore over-reads, often by a factor of two. A fluorometer binds the target and ignores the rest.
That gap is why our sample requirement tables say to increase concentrations by roughly 2× when you measured on a Nanodrop. Getting the real figure before a cohort goes to library preparation costs a fraction of the run it protects.
When it makes sense on its own
Four situations come up regularly:
- Before committing a whole cohort to sequencing, in-house or elsewhere.
- After long storage, when integrity may have drifted.
- After a failed or disappointing run, to establish whether the input was the cause.
- When a collaborator or a reviewer wants a documented, independent measurement.
Report
The report
The QC report is delivered in your client portal, as a PDF with a verifiable, time-stamped fingerprint, alongside your data files to download. If the project continues on another platform, its results arrive in the same project, so you keep one continuous record; where available, such as transcriptomics, they can also be explored as interactive results. Input requirements are on the DNA and RNA pages.
Not sure which service fits?